Multi-E4-MU

Universal measuring transducer with Ethernet interface

with HTTP, TCP/IP, Modbus-TCP protocol with 4 bipolar configurable analog outputs 2 limit value or pulsed outputs

SKU: Multi-E4-MU Categories: ,

Description

Universal measuring transducer with Ethernet interface with HTTP, TCP/IP, Modbus-TCP protocol with 4 bipolar configurable analog outputs 2 limit value or pulsed outputs

Application
The measuring transducer Multi-E4-MU is used for the simultaneous transformation and isolation of current, voltage, frequency, active and reactive power, apparent power and the power factor for sinusoidal quantities into 4 impressed direct current and direct voltage signals. The measurement is possible in alternating current systems and 3-wire or 4-wire three-phase power systems with same or any load. The 29 measurands may be displayed, stored and configured via a 10 Mbit/sec Ethernet LAN interface at the PC. Up to 13000 series of measured values may be stored in the internal memory of the measuring transducer. Furthermore, the measuring results may be displayed via web browser or be read and further processed via HTTP, TCP/IP or Modbus-TCP protocol. Two further outputs may be used as limit value or pulsed outputs. The switching status of the limit value or pulsed outputs is indicated by 2 LEDs.

Function
The parameters to be measured are sent to a 22 bit A/D converter with a sample rate of >20 kSPS via current and voltage transformers and are then further transmitted to a microcontroller which calculates the required values for the outputs from the measured parameters. The output values for current and voltage are rms-values. The frequency is calculated from the period of the voltage signal of phase L1. The active powers are calculated from the products of the samples of current and voltage of the three phases. The calculations of the reactive power of the three phases are done using the product of the samples of the currents and the 90° offset voltage signals. The apparent power is the sum of the products from the three rms-values of current and voltage.
The power factors are calculated from the apparent power values and the active power values. The output amplifiers supply impressed direct current and direct voltage signals. The output signals are galvanically isolated from the input signals and the auxiliary voltage, but linked to each other via a common ground wire. The outputs are no-load proof and short-circuit proof. The two limit value and pulsed outputs are galvanically isolated from all inputs and outputs and the auxiliary voltage. An auxiliary voltage is required.

Downloads
PDF-general description
PDF-product description
PDF-operating manual
PDF-software description
Software for Multi-E4-M

Enquiry

    Müller + Ziegler GmbH

    Industriestraße 23
    91710 Gunzenhausen
    GERMANY

    Tel.: +49 9831 5004-0
    E-Mail: info@mueller-ziegler.de

    Opening hours

    Monday – Thursday
    07:00 – 12:00 h
    13:00 – 16:00 h

    Friday
    07:00 – 12:00 h

    Back To Top